200A RSBTT III Transformer Test Bench For Laboratory Or Workshop

Ask Latest Price
Video Channel
Brand Name :RISING
Model Number :RSBTT III
Certification :ISO CE
Place of Origin :China
MOQ :1 Set
Payment Terms :T/T, Western Union, MoneyGram,L/C, D/A, D/P,
Supply Ability :100 SET PER Month
Delivery Time :20 working days
Packaging Details :Wooden package for export
Voltage :0.1-600V
Current :0.1-200A
Power factor :0.1-0.9999
Power supply :AC220V±10% 50Hz±2%
Working temperature :0-40℃
Relative humidity :30%-90%
Outline dimension :Customization
Color :White
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Automatic Comprehensive 22kV Capacity 2000kVA Transformer Routine Testing Equipment for Laboratory or Workshop

Product Description

1.The experimental subject for the equipment that Party A purchased from Party B meet the following requirements:

■ 35kV ordinary power transformers and special transformers, capacity 20000kVA and below;

2 The experimental subject for the equipment that Party A purchased from Party B must meet the following requirements of voltage classes:

The impedance of the tested transformer is less than 8%, the voltage class is:

■ HV side 35kV, etc.

■ 0.4kV~10kV.LV side:0.4kV~10kV.

3. The experimental subject for the equipment that Party A purchased from Party B meet the following requirements of tested capacity:

HV side voltage level 22kV capacity 2000kVA and below.

4. The experimental subject for the equipment that Party A purchased from Party B must meet the following test requirements:

4.1 Routine testing

■ Transformer no-load current percentage and no-load loss testing;

■ Transformer short-circuit impedance percentage and load loss testing;

■ Transformer power frequency withstand voltage testing;

■ Transformer frequency doubling induced withstand voltage testing;

5 Based on the analysis of experimental ability, the experimental subject for the equipment that Party A purchased from Party B meet the following test ability:

5.1 No-load and load loss test ability

■ For the voltage level of 0.4kV/33kV distribution transformer, it’s ok to use the direct low-voltage circuit testing for no-load and load loss.

■ In conclusion, High voltage current transformer of the variable ratio gear selection (Rated working voltage:3KV): 200/1,100/1,50/1,30/1,20/1,10/1,5/1,1A/1A, total:8 speed, precision grade:0.05%; voltage transformer of the variable ratio gear selection: 3kV/100V,2kV/100V,1KV/100V,0.5KV/100V,total:4 speed, precision grade:0.05%.

Feature/Function
Test ability:
1)Can meet the capacity of 63000KvA, 110Kv and below the oil-immersed transformer (including S9 S11 S13 and amorphous alloy transformer);
2) It can meet the capacity of 31500KvA, 35Kv and below dry-type transformers;
3) Mine explosion-proof transformers that can meet capacity of 6300KvA, 10Kv and below;

4) Special transformer (need to inform detailed capacity and voltage level when ordering).

Test item:

1) Transformer winding resistance test

2) Transformer voltage ratio measurement and connection group number test

3) Transformer no-load current (%) and no-load loss test

4) Transformer short circuit impedance (%) and load loss test

5) Transformer power frequency applied pressure test

6) Transformer induced withstand voltage test

Extensible test project:

1) Transformer partial discharge test

2) No-load harmonic test (0-31th harmonic)

3) Withstand voltage test of transformer oil (0-80Kv)

4) Transformer temperature rise test (can automatically draw temperature rise curve)

5) Insulation resistance test (absorption ratio and polarization index)

6) Transformer anti-interference dielectric loss test

7) Lightning impact test.

Performance indicators:

1. Tested transformer parameters

1.1 Transformer capacity under test (to meet temperature rise test condition, dry type transformer)

10kV level ≤2500KVA

35kV level ≤6300kVA

1.2 Tested transformer voltage level below 35kV on primary side

2. Accuracy

2.1 Voltage Range 0-22kV

2.2 Current Range 0-400A

2.3 Minimum voltage resolution 0.001V* PT ratio

2.4 Minimum current resolution 0.0001A*CT ratio

2.5 Power Minimum Resolution 0.1W*PT Ratio*CT Ratio

2.6 Ambient temperature -10~45°C

2.7 Using Relative Humidity 85%