Power Frequency 3000KVA High Voltage Test System For Generator

Ask Latest Price
Brand Name :RISING
Model Number :RSXZ-L
Certification :ISO CE
Place of Origin :China
MOQ :1
Supply Ability :500 SET PER Month
Delivery Time :5-8 days
Packaging Details :Wooden package for export
Power :Electronic
Rated output voltage :0~60kV(AC effective value)
Output Frequency :50Hz
Working Mode :Full power continuous working time: 1min
Resonate voltage waveform :Sine wave, distortion ≤1%
Quality Factor :10~40
Maximum measured capacity :≤3000kVA
Power supply :380V±10%, frequency:50Hz
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

RSXZ-L Power Frequency Series Resonant Withstand Voltage Tester System for Generator Dynamo

Product Features
1. The device with large output capacity and small power capacity, low cost, easy to operate and safe.
2. Serial resonant system actually is current filter circuit, make the current which through it be fundamental current, the output voltage distortion (THD) is very small, and better than all the AC voltage withstand equipment.
3. The short circuit current after flashover or breakdown is only less than 1/10 (1/Q) of the measured current, can effectively prevent the damage to fault point after breakdown.
4. Auto blowout the arc after flashover, it is a long and stable process to recover the serial resonant voltage, safe.
Tecnical parameters
Rated output voltage 0~60kV(AC effective value)
Output frequency 50Hz
Resonate voltage waveform Sine wave, distortion ≤1%
Working mode Full power continuous working time: 1min
Quality factor 10~40
Maximum measured capacity ≤3000kVA
Power supply 380V±15%, frequency:50Hz

Serial product and application:

Model Application (AC voltage withstand test for generator which voltage ≤20kV,measured frequency: 50Hz)
Control cabinet Regulator Reactor(dry type) Excitation transformer (dry type) Divider Application

200/25
30kW 30kVA
(electric)
200kVA/25kV
adjustable 1 set
30kVA
(dry type)
30kV Hydroelectric generator
0.4-1.0μF
(10kV/40MW)

300/50
60kW 60kVA
(electric)
300kVA/50kV
adjustable 1 set
60kVA
(oil immersed)
50kV Thermoelectric generator
0.27-0.33μF
(20kV/300MW)

600/50
60kW 60kVA
(electric)
200kVA/50kV
adjustable 1 set
400kVA/50kV
adjustable 1 set
60kVA
(oil immersed)
50kV Thermoelectric generator
0.113-0.45μF
(20kV/600MW)

1200/50
120kW 120kVA
(inductive)
200kVA/50kV
fixed 2 sets
800kVA/50kV
adjustable 1 set
120kVA
(oil immersed)
50kV Thermoelectric generator
0.6-1.8μF
(20kV/250MW)

2750/55
300kW 300kVA
(inductive)
750kVA/55kV
fixed 2 sets
1250kVA/55kV
adjustable 1 set
300kVA
(oil immersed)
60kV Thermoelectric generator
1.6-3.3μF
(20kV/770MW)

Note: make the solution according the measured equipment.