HV Impulse Voltage Test System For Lightning Test

Ask Latest Price
Brand Name :RISING
Model Number :RSCJ-V
Certification :ISO CE
Place of Origin :China
MOQ :1
Supply Ability :500 SET PER Month
Delivery Time :5-8 days
Packaging Details :Wooden package for export
Power :Electronic
Standard voltage(kV) :±300-±900/±1000-±1600/±1800-±2400/±2800-±3200/±3600-±48
Impact capacity (μF) :0.133-0.111/0.05-0.0937/0.056-0.0833/0.0357-0.0625/0.0278-
Impact energy (kJ) :6-45/25-120/90-240/140-320/80-240
Stage voltage (kV) :±100/±200
Weight (kg) :547-1378/1366-1880/7353-11574/10266-15680/15480-23500
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

RSCJ-V AC HV Impulse High Voltage Impulse Voltage Test System for Lightning Test

Product Description

Impulse voltage generator is mainly used for full wave of lightning impulse voltage, lightning impulse voltage clipping wave and operation impulse voltage wave test of electric power equipment, etc., to test insulation performance. Impulse voltage generator a power supply device that mimics the impulse voltage of lightning and operating overvoltage. It is mainly used in insulation shock withstand voltage and dielectric shock breakdown, discharge and other tests.

The device can provide a complete set of impulse voltage (current) generators of various waveform series. The impact test device is mainly composed of generator body, cut-off wave, voltage divider, four-component console (the console is divided into microcomputer type and common type), digital waveform recording system, etc.

Product Features

  1. 1. Small loop inductance and band-stop filtering measures can produce standard shock wave under large capacitance load with large load capacity.

    2. High voltage utilization coefficient, no less than 85% and 80% of thunder wave and operation wave respectively.

    3, Wave modulation convenient, simple operation, good synchronization performance, reliable action.

    4, The use of constant current charging automatic control technology, high degree of automation, strong anti-interference ability.

Technical parameters

Standard Voltage(kv) Impact capacity(μF) Levels of capacitance(μF) Impact energy(kJ) Level of voltage(kv) Level Weight(kg)
±300 - ±900 0.133-0.111 0.4-1 6-45 ±100 3-9 547-1378
±1000 - ±1600 0.05-0.0937 0.5-1.5 25-120 ±100 10-16 1366-1880
±1800 - ±2400 0.05-0.0833 0.5-1.5 90-240 ±200 9-12 7353-11574
±2800 - ±3200 0.0357-0.0625 0.5-1.5 140-320 ±200 14-16 10266-15680
±3600 - ±4800 0.0278-0.03125 0.5-2 80-240 ±200 18-24 15480-23500